BRAND | KIMO |
Product | SCOH-112 |
Description | Multifunction probe |
Internal code | IMP4487512 |
Technical specification | Multifunction probe (CO2 air quality, humidity, temperature) with handle and multi-function button The probe features the latest automatic SMART probe recognition system Measuring ranges: CO2 content: 0... up to 5000 ppm Humidity: 5... + 95% RH Temperature: -20... up to +80°C Including alignment certificate (test certificate) Art.-No.: 56-24776 |
Discover the superior quality and performance of the KIMO SCOH-112 with Impexron GMBH in Australia . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The SCOH-112 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of SCOH-112 :
At Impexron GMBH , we offer the SCOH-112 at competitive prices and with the fastest delivery times across Australia . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the SCOH-112 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply KIMO products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Temperature probe Type: FKI-3-1000-MM (thermocouple type K) Measuring range: -40 ... + 1000 ° C Diameter: 3 mm Probe length. 1000 mm / incl miniature connector
Thermocouple - temperature sensor with terminal head Technical specifications: Temperature range: -40 .. + 750 ° C Design: Type J Fe-Con (JI isolated) Probe diameter: 6 mm Probes - Length: 900 mm Type: TB-JI-6-900
Infrared thermometer, KIRAY 200 with laser pointer IR measurement range: -50 to + 850 ° C D.S. .: 30: 1 with input for thermocouple Measuring range for the supplied thermocouple: -40 ... + 400 ° C Measurement range for temperature display: -50 ... + 1370 ° C features: Adjustable emissivity: from 0.1 to 1.0 Backlight, min-max function, audible alarm (high, low) Included: external Thermocouple type K (cable sensor), Carrying case and operating instructions
Digital luxmeter - Class B (standard NF C 42-710) Measuring range: 0.1 ... 200 000 Lux Functions: Hold, Min / max, average, and much more ... with data storage and comprehensive evaluation Scope of supply: calibration, soft case carrying case evaluation
KISTOCK Data Logger Type: KH-110-AO with display Data storage: 16,000 data points (2 adjustable visual alarm signals) Internal measuring ranges: Environment - Humidity: 5 ... 95% Ambient temperature: -20 ... + 70 ° C Light sensor: 0 to 10,000 Lux .... Housing with magnetic holder Protection: IP40
Air velocity / flow transmitter Type: CTV210-BOO with display incl. non-directional flow probe for very low flow rates Probe length: 300 mm Height: 85 mm Cable length: 2 m (other lengths available) Measuring ranges: Air velocity: 0 ... up to 5 m / s Flow 0 ... 100 000 m³ / h Temperature 0 ... 50 ° C (Pt100 - Sensor 1/3 DIN) outputs: 2 analogue outputs 4-20 mA or 0-10 V Supply voltage: 24 V AC / DC ABS housing, IP 65
with large color display - recording of measurements up to 12,000 measuring points
Hand device for CO2 measurements Type: AQ 100 S Measuring range: 0 ... 5000 ppm . Temp Range: -20 ... +80 ° C
[Sleeve for handheld instrument of the 300 series of shockproof material with magnet, shoulder strap and practical stand Item No .: 56-17053]
CP 202-BO obsolete,replaced by CP212-BO
differential pressure transmitter, IP 65, 0 +/- 100 mmCE, 4-20 mA and 0-10 V 2 outputs,RS 232, 6A/230 VA.C. SQR debi, LCC-300
Differential pressure transmitter
Differential pressure transmitter with display Pressure measuring range: -1000 / +1000 Pa (Optional is also the possibility of a Air velocity and flow function) Temperature input: Pt100 of -100..bis + 400 ° C Auto Zero: Through key or atom. with solenoid valve Accuracy: +/- 0.5% of the measured value Power supply: 24V AC / DC 2 analogue outputs 0-10 V or 4-20 mA / 0-20 mA PC interface: USB Mini DIN Housing: ABS, IP 65
The Differential Pressure Transmitters
Lufgeschwindigkeit and temperature transmitter
Air velocity and temperature transmitter
Gas detector for the detection of gas leaks Type: FG 100 S with Backlight
Thermo-/ Hygrometer
Temperature / Humidity - handheld instrument
Flue gas analyzer
Konfigurations-Software für Transmitter der 110 / 210 / 310 Serie
ifferenzdruck-Schalter
Vane Thermo-Anemometer / handheld instrument Measuring range: Air Speed: 0.25 ... to 35 m / s flow rate: 0 .... to 99999 m³ / h Temperature: -20 to +80 ° C .... Delivery consisting of: - vane Ø 100 mm - Transport case - Calibration Certificate No .: 56-16421 Customs Tariff No .: 9025 8091
Mikromanometer
(Measuring units available in: Pa, mmH2O, INWG, DaPa Measuring range: 0 ... + / - 1000 mm H2O (10 kPa) Pressure resistance: 700 mbar Delivery consisting of: silicone tubing (2 x 1 m) Transport case Calibration Certificate and Item No .: 56-16416 Tariff No .: 9025 8040)
Precision Thermo Micromanometer
Flow function